Know the Low-speed Handpieces Commonly Used in Dentistry

Know the Low-speed Handpieces Commonly Used in Dentistry

2022-07-22 16:41:30

Compared with high-speed handpieces, low-speed handpieces have a relatively low speed, which is also called slow phones. According to the classification of the catalog of medical devices, they belong to class II medical devices.

 

low speed handpiece

 

The low-speed handpiece is divided into two parts, one is the motor, and the other is the handpiece body. When using, you need to first install the motor on the dental chair, then install the low-speed handpiece on the motor, and then install the upper needle, and use the foot pedal to control the rotation and stop, to operate.

 

Low-speed handpieces are divided into the straight machine and the bending machine. A straight machine is used for grinding outside the mouth. When there is no special grinder at hand, we use it to polish dentures or temporary crowns. The needle it uses is generally called the grinding head, which is generally common with the grinding head of the grinding machine.

 

If you need to polish more and have a special technician room, you'd better be in the technician room, otherwise, it's difficult to clean where the debris flies.

 

A bending machine is commonly used for intraoral operation. Before use, it needs to install a needle, pull out the paddle on the back, insert the needle, and then buckle the paddle back, check whether it is tightly installed, and then it can be used. The same operation is required when disassembling.

 

The bending machine can be used to remove decay when filling teeth, and also can be used to lift and remove the top of the pulp chamber with a small ball drill after pulpotomy. Our g-drill, p-drill, and polishing cups are also installed on low-speed handpieces for polishing after tooth washing, taking out the dental glue tip, preparing the fiber post, and so on. Usually, it does not need water spray, so low-speed handpieces generally have no water path or use the design of an external water path, We should pay attention not to step on the foot of the waterway when stepping the foot, otherwise, the water will spray everywhere.

 